ATEN PE8208

  • Remote power outlet control (On, Off, Power Cycle) by individual outlets
  • Real-time current, voltage, and kWH displayed in a browsed-based UI for monitoring at the outlet level (PE8108 / PE8208)
  • Network Interfaces: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Ping, Telnet
  • Power-on sequencing – users can set the power on sequence and delay time for each port to allow equipment to be turned on in the proper order
Category: Tags: , , , , Brand:

ATEN PE8208

20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU

 

 8 outlets
• 20A (UL derated 16A) / 16A
• Outlet Power Measurement

The PE8208 eco PDU is intelligent PDUs that contains 8 AC outlets and is available in various IEC or NEMA socket configurations. It provides secure, centralized, intelligent, power management (power on, off, cycle) of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center’s health environment via sensors*.

The eco PDUs offer remote power control combined with real-time power measurement – allowing you to control and monitor the power status of devices attached to the PDUs, either at the PDU device or outlet level, from practically any location via a TCP/IP connection.

eco PDU supports any 3rd party v3 SNMP Manager Software and eco DC (Energy Management Web GUI). eco DC provides you with an easy method for managing multiple devices, offering an intuitive and user friendly Graphical User Interface that allows you to configure a PDU device and monitor power status of the equipment connected to it. With eco DC, the Sensor-enabled eco PDU also offers comprehensive power analysis reports which can separate by departments and locations, providing precise measurements of current, voltage, power and watt-hour in a real-time display.

With its advanced security features and ease of operation, the eco PDU is the most convenient, most reliable, and most cost effective way to remotely manage power access for multiple computer installations and allocate power resources in the most efficient way possible.

Note: Sensors are optional accessories. A sensor-enabled installation is required to generate a more complete energy-efficient data and chart. Higher sensor installation density is helpful to generate more accurate data.

pdu

Spesification

Function PE8208A PE8208B PE8208G PE8208Z
Electrical
Nominal Input Voltage 100 – 120 VAC 100 – 240 VAC 100 – 240 VAC 100 – 240 VAC
Maximum Input Current 20A Max; 16A(UL de-rated) 20A Max; 16A(UL de-rated) 16A Max 16A Max
(For Australia : 15A )
Input Frequency 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz
Input Connection NEMA 5-20P NEMA 6-20P IEC 60320 C20 IEC 60320 C20
Input Power 2400 VA(Max); 1920 VA(UL de-rated) 4160 VA(Max); 3328 VA(UL de-rated) 3680 VA(Max) 3680VA(Max)
Outlet Type Total : 8 x NEMA 5-20R Total : 7 x IEC320 C13 + 1 x IEC320 C19 Total : 7 x IEC320 C13 + 1 x IEC320 C19 Total : 7 x GB1002 10A+ 1 x GB1002 16A
Nominal Output Voltage 100 – 120 VAC 100 – 240 VAC 100 – 240 VAC 100 – 240 VAC
Maximum Output Current (Outlet) NEMA 5-20R: 20A(Max); 16A(UL de-rated) C13: 15A(Max); 12A(UL de-rated)
C19: 20A(Max); 16A(UL de-rated)
C13: 10A(Max)
C19: 16A(Max)
GB1002 : 16A(Max),
GB1002 : 10A(Max)
Maximum Output Current (Bank) 20A(Max); 16A(UL de-rated) 20A(Max); 16A(UL de-rated) 16A(Max) 16A (Max)
Maximum Output Current (Total) 20A(Max); 16A(UL de-rated) 20A(Max); 16A(UL de-rated) 16A(Max) 16A (Max)
Breakers 1 x 20A Non-Fuse Breaker 1 x 20A Non-Fuse Breaker 1 x 16A Non-Fuse Breaker 1 x 16A Non-Fuse breaker
Metering Outlet level Current, Voltage, VA , PF and KWh Monitoring Outlet level Current, Voltage, VA , PF and KWh Monitoring Outlet level Current, Voltage, VA , PF and KWh Monitoring Outlet level Current, Voltage, VA , PF and KWh Monitoring
Outlet Switching Yes Yes Yes Yes
Environment Sensor Ports 2 2 2 2
Metering Accuracy Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Physical Properties
Dimensions (L x W x H) 43.24 x 22.04 x 4.40 cm
(17.02 x 8.68 x 1.73 in.)
43.24 x 22.04 x 4.40 cm
(17.02 x 8.68 x 1.73 in.)
43.24 x 22.04 x 4.40 cm
(17.02 x 8.68 x 1.73 in.)
43.24 x 22.04 x 4.40 cm
(17.02 x 8.68 x 1.73 in.)
Weight 2.84 kg ( 6.26 lb ) 2.84 kg ( 6.26 lb ) 2.84 kg ( 6.26 lb ) 2.84 kg ( 6.26 lb )
Power Cord Length 3 m 3 m 3 m 3 m
Environmental
Temperature (Operating / Storage) 0 – 50°C / -20 – 60°C 0 – 50°C / -20 – 60°C 0 – 50°C / -20 – 60°C 0 – 50°C / -20 – 60°C
Humidity (Operating & Storage) 0 – 80% RH, Non-Condensing 0 – 80% RH, Non-Condensing 0 – 80% RH, Non-Condensing 0 – 80% RH, Non-Condensing
Compliance
EMC Verification FCC, Others by Request FCC, Others by Request CE, Others by Request CE, Others by Request
Safety Verification UL, Others by Request UL, Others by Request CE-LVD, GOST, Others by Request CE-LVD, Others by Request
Note For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.